]> git.tdb.fi Git - ext/subsurface.git/commit
Remove redundant duplicate pressure samples
authorLinus Torvalds <torvalds@linux-foundation.org>
Thu, 17 Nov 2011 14:03:11 +0000 (12:03 -0200)
committerLinus Torvalds <torvalds@linux-foundation.org>
Thu, 17 Nov 2011 14:03:11 +0000 (12:03 -0200)
commitc486a9ee81de77faba90b5aa0b2e63eb11ec47f8
treea8a0aaf03a7b1dc3b91d8a0cdcd166c6975b50e3
parent1268e0d22597593e3276ffa574e7eeb679d0dbd2
Remove redundant duplicate pressure samples

At least the Suunto pressure transmitter seems to be pretty
"quantisized", and it will send identical samples for a while until the
pressure changes enough.  Then subsurface gives this silly flat line
with a sudden jump downwards, which *could* be you suddenly taking a
deep breath after holding it for a while, but almost certainly it's a
sensor issue.

So just remove successive identical pressure readings.  They aren't
interesting, and subsurface will actually do a good job of interpolating
it according to SAC rate instead.  And they just make the XML look
worse.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
dive.c